6.3.4 Direct-solution steady-state dynamic analysis

Products: ABAQUS/Standard  ABAQUS/CAE  

References

Overview

A direct-solution steady-state dynamic analysis:

  • is used to calculate the steady-state dynamic linearized response of a system to harmonic excitation;

  • is a linear perturbation procedure;

  • calculates the response directly in terms of the physical degrees of freedom of the model;

  • is an alternative to mode-based steady-state dynamic analysis, in which the response of the system is calculated on the basis of the eigenmodes;

  • is more expensive computationally than mode-based or subspace-based steady-state dynamics;

  • is more accurate than mode-based or subspace-based steady-state dynamics, in particular if significant frequency-dependent material damping or viscoelastic material behavior is present in the structure; and

  • is able to bias the excitation frequencies toward the approximate values that generate a response peak.

Introduction

Steady-state dynamic analysis provides the steady-state amplitude and phase of the response of a system due to harmonic excitation at a given frequency. Usually such analysis is done as a frequency sweep by applying the loading at a series of different frequencies and recording the response; in ABAQUS/Standard the direct-solution steady-state dynamic procedure conducts this frequency sweep. In a direct-solution steady-state analysis the steady-state harmonic response is calculated directly in terms of the physical degrees of freedom of the model using the mass, damping, and stiffness matrices of the system.

When defining a direct-solution steady-state dynamic step, you specify the frequency ranges of interest and the number of frequencies at which results are required in each range (including the bounding frequencies of the range). In addition, you can specify the type of frequency spacing (linear or logarithmic) to be used, as described below (“Selecting the frequency spacing”). Logarithmic frequency spacing is the default. Frequencies are given in cycles/time.

Those frequency points for which results are required can be spaced equally along the frequency axis (on a linear or a logarithmic scale), or they can be biased toward the ends of the user-defined frequency range by introducing a bias parameter (described below).

The direct-solution steady-state analysis procedure can be used in the following cases for which the eigenvalues cannot be extracted (and, thus, the mode-based steady-state dynamics procedures are not applicable):

  • for nonsymmetric stiffness;

  • when any form of damping other than modal damping must be included; and

  • when viscoelastic material properties must be taken into account.

While the response in this procedure is linear, the prior response can be nonlinear. Initial stress effects (stress stiffening) as well as load stiffness effects will be included in the steady-state dynamics response if nonlinear geometric effects (General and linear perturbation procedures, Section 6.1.2) were included in any general analysis step prior to the direct-solution steady-state dynamic procedure.

Input File Usage:           
*STEADY STATE DYNAMICS, DIRECT

ABAQUS/CAE Usage: 

Step module: Create Step: Linear perturbation: Steady-state dynamics, Direct


Ignoring damping

If damping terms can be ignored, you can specify that a real, rather than a complex, system matrix be factored, which can significantly reduce computational time. Damping is discussed below.

Input File Usage:           
*STEADY STATE DYNAMICS, DIRECT, REAL ONLY

ABAQUS/CAE Usage: 

Step module: Create Step: Linear perturbation: Steady-state dynamics, Direct: Compute real response only


Selecting the type of frequency interval for which output is requested

Two types of frequency intervals are permitted for output from a direct-solution steady-state dynamic step. If an eigenvalue extraction step precedes the direct-solution steady-state dynamic step, you can select either the range or the eigenfrequency type of frequency interval; otherwise, only the range type can be used.

Dividing the specified frequency range using the user-defined number of points and the optional bias function

For the range type of frequency interval (the default), the specified frequency range of interest is divided using the user-defined number of points and the optional bias function.

Input File Usage:           
*STEADY STATE DYNAMICS, DIRECT, INTERVAL=RANGE

ABAQUS/CAE Usage: 

Step module: Create Step: Linear perturbation: Steady-state dynamics, Direct: toggle off Use eigenfrequencies to subdivide each frequency range


Specifying the frequency ranges by using the system's eigenfrequencies

If the direct-solution steady-state dynamic analysis is preceded by an eigenfrequency extraction step, you can select the alternative eigenfrequency type of frequency interval. The following intervals then exist in each frequency range:

  • First interval: extends from the lower limit of the frequency range given to the first eigenfrequency in the range.

  • Intermediate intervals: extend from eigenfrequency to eigenfrequency.

  • Last interval: extends from the highest eigenfrequency in the range to the upper limit of the frequency range.

For each of these intervals the frequencies at which results are calculated are determined using the user-defined number of points (which includes the bounding frequencies for the interval) and the optional bias function. Figure 6.3.4–1 illustrates the division of the frequency range for 5 calculation points and a bias parameter equal to 1.

Input File Usage:           
*STEADY STATE DYNAMICS, DIRECT, INTERVAL=EIGENFREQUENCY

ABAQUS/CAE Usage: 

Step module: Create Step: Linear perturbation: Steady-state dynamics, Direct: Use eigenfrequencies to subdivide each frequency range


Figure 6.3.4–1 Division of range for the eigenfrequency type of interval and 5 calculation points.

Selecting the frequency spacing

Two types of frequency spacing are permitted for a direct-solution steady-state dynamic step. For the logarithmic frequency spacing (the default), the specified frequency ranges of interest are divided using a logarithmic scale. Alternatively, a linear frequency spacing can be used if a linear scale is desired.

Input File Usage:           Use either of the following options:
 
*STEADY STATE DYNAMICS, DIRECT, 
FREQUENCY SCALE=LOGARITHMIC
*STEADY STATE DYNAMICS, DIRECT, FREQUENCY SCALE=LINEAR

ABAQUS/CAE Usage: 

Step module: Create Step: Linear perturbation: Steady-state dynamics, Direct: Scale: Logarithmic or Linear


Requesting multiple frequency ranges

You can request multiple frequency ranges or multiple single frequency points for a direct-solution steady-state dynamic step.

Input File Usage:           
*STEADY STATE DYNAMICS, DIRECT
lower_frequency1, upper_frequency1, number_of_points1, bias_parameter1
lower_frequency2, upper_frequency2, number_of_points2, bias_parameter2
...
single_frequency1
single_frequency2
...
Repeat the data lines as often as necessary. When both frequency ranges and additional single frequency points are requested, the frequency ranges must be specified first.

ABAQUS/CAE Usage: 

Step module: Create Step: Linear perturbation: Steady-state dynamics, Direct: Data: enter data in table, and add rows as necessary


The bias parameter

The bias parameter can be used to provide closer spacing of the results points either toward the middle or toward the ends of each frequency interval. Figure 6.3.4–2 shows a few examples of the effect of the bias parameter on the frequency spacing.

Figure 6.3.4–2 Effect of the bias parameter on the frequency spacing for a number of points .

The bias formula used in direct-solution steady-state dynamics is

where

;

n

is the number of frequency points at which results are to be given;

is one such frequency point ();

is the lower limit of the frequency range;

is the upper limit of the range;

is the frequency at which the th results are given;

is the bias parameter value; and

is the frequency or the logarithm of the frequency, depending on the value chosen for the frequency scale.

A bias parameter, , that is greater than 1.0 provides closer spacing of the results points toward the ends of the frequency interval, while values of that are less than 1.0 provide closer spacing toward the middle of the frequency interval. The default bias parameter is 1.0 for a range frequency interval and 3.0 for an eigenfrequency interval.

Damping

If damping is absent, the response of a structure will be unbounded if the forcing frequency is equal to an eigenfrequency of the structure. To get quantitatively accurate results, especially near natural frequencies, accurate specification of damping properties is essential. The various damping options available are discussed in Material damping, Section 12.1.1.

In direct-solution steady-state dynamics damping can be created by dashpots (see Dashpots, Section 18.2.1), by “Rayleigh” damping associated with materials and elements (see Material damping, Section 12.1.1), and by viscoelasticity included in the material definitions (see Frequency domain viscoelasticity, Section 10.7.2).

When a real-only system matrix is factored, all forms of damping are ignored, including quiet boundaries on infinite elements and nonreflecting boundaries on acoustic elements.

Initial conditions

The base state is the current state of the model at the end of the last general analysis step prior to the steady-state dynamic step. If the first step of an analysis is a perturbation step, the base state is determined from the initial conditions (Initial conditions, Section 19.2.1). Initial condition definitions that directly define solution variables, such as velocity, cannot be used in a steady-state dynamic analysis.

Boundary conditions

In a steady-state dynamic analysis the real and imaginary parts of any degree of freedom are either restrained or unrestrained simultaneously; it is physically impossible to have one part restrained and the other part unrestrained. ABAQUS/Standard will automatically restrain both the real and imaginary parts of a degree of freedom even if only one part is prescribed specifically. The unspecified part will be assumed to have a perturbation magnitude of zero.

Boundary conditions can be applied to any of the displacement or rotation degrees of freedom (1–6) in a direct-solution steady-state analysis. See Boundary conditions, Section 19.3.1. These boundary conditions will vary sinusoidally with time. You specify the real (in-phase) part of a boundary condition and the imaginary (out-of-phase) part of a boundary condition separately.

Input File Usage:           Use either of the following options to define the real (in-phase) part of the boundary condition:
 
*BOUNDARY
*BOUNDARY, LOAD CASE=1

Use the following option to define the imaginary (out-of-phase) part of the boundary condition:

*BOUNDARY, LOAD CASE=2

ABAQUS/CAE Usage: Load module: boundary condition editor: real (in-phase) part + imaginary (out-of-phase) part i

Frequency-dependent boundary conditions

An amplitude definition can be used to specify the amplitude of a boundary condition as a function of frequency (Amplitude curves, Section 19.1.2).

Input File Usage:           Use both of the following options:
 
*AMPLITUDE, NAME=name
*BOUNDARY, LOAD CASE=n, AMPLITUDE=name

ABAQUS/CAE Usage: Load or Interaction module: Create Amplitude: Name: name

Load module: boundary condition editor: real (in-phase) part + imaginary (out-of-phase) part i: Amplitude: name


Loads

The following loads can be prescribed in a steady-state dynamic analysis:

These loads are assumed to vary sinusoidally with time over a user-specified range of frequencies. Loads are given in terms of their real and imaginary components.

Coriolis distributed loading adds an imaginary antisymmetric contribution to the overall system of equations. This contribution is currently accounted for in solid and truss elements only and is activated by using the unsymmetric matrix storage and solution scheme for the step (Procedures: overview, Section 6.1.1).

Fluid flux loading cannot be used in a steady-state dynamic analysis.

Input File Usage:           Use any of the following options to define the real (in-phase) part of the load:
 
*CLOAD or *DLOAD
*CLOAD or *DLOAD, LOAD CASE=1

Use either of the following options to define the imaginary (out-of-phase) part of the load:

*CLOAD or *DLOAD, LOAD CASE=2

ABAQUS/CAE Usage: Load module: load editor: real (in-phase) part + imaginary (out-of-phase) part i

Frequency-dependent loading

An amplitude definition can be used to specify the amplitude of a load as a function of frequency (Amplitude curves, Section 19.1.2).

Input File Usage:           Use both of the following options:
 
*AMPLITUDE, NAME=name
*CLOAD or *DLOAD, LOAD CASE=n, AMPLITUDE=name

ABAQUS/CAE Usage: Load or Interaction module: Create Amplitude: Name: name

Load module: load editor: real (in-phase) part + imaginary (out-of-phase) part i: Amplitude: name


Predefined fields

Predefined temperature fields can be specified in direct-solution steady-state dynamic analysis (see Predefined fields, Section 19.6.1) and will produce harmonically varying thermal strains if thermal expansion is included in the material definition (Thermal expansion, Section 12.1.2). Other predefined fields are ignored.

Material options

As in any dynamic analysis procedure, mass or density (Density, Section 9.2.1) must be assigned to some regions of any separate parts of the model where dynamic response is required. If an analysis is desired in which the inertia effects are neglected, the density should be set to a very small number. The following material properties are not active during steady-state dynamic analyses: plasticity and other inelastic effects, thermal properties (except for thermal expansion), mass diffusion properties, electrical properties (except for the electrical potential, , in piezoelectric analysis), and pore fluid flow properties—see General and linear perturbation procedures, Section 6.1.2.

Viscoelastic effects can be included in direct-solution steady-state harmonic response analysis. The linearized viscoelastic response is considered to be a perturbation about a nonlinear preloaded state, which is computed on the basis of purely elastic behavior (long-term response) in the viscoelastic components. Therefore, the vibration amplitude must be sufficiently small so that the material response in the dynamic phase of the problem can be treated as a linear perturbation about the predeformed state. Viscoelastic frequency domain response is described in Frequency domain viscoelasticity, Section 10.7.2.

Elements

Any of the following elements available in ABAQUS/Standard can be used in a steady-state dynamic procedure:

  • stress/displacement elements (other than generalized axisymmetric elements with twist);

  • acoustic elements;

  • piezoelectric elements; or

  • hydrostatic fluid elements.

See Choosing the appropriate element for an analysis type, Section 13.1.3.

Output

In direct-solution steady-state dynamic analysis the value of an output variable such as strain (E) or stress (S) is a complex number with real and imaginary components. In the case of data file output the first printed line gives the real components while the second lists the imaginary components. Results and data file output variables are also provided to obtain the magnitude and phase of many variables (see ABAQUS/Standard output variable identifiers, Section 4.2.1). In the case of data file output the first printed line gives the magnitudes while the second lists the phase angle.

The following variables are provided specifically for steady-state dynamic analysis:

Element integration point variables:
PHS

Magnitude and phase angle of all stress components.

PHE

Magnitude and phase angle of all strain components.

PHEPG

Magnitude and phase angles of the electrical potential gradient vector.

PHEFL

Magnitude and phase angles of the electrical flux vector.

PHMFL

Magnitude and phase angle of the mass flow rate in fluid link elements.

PHMFT

Magnitude and phase angle of the total mass flow in fluid link elements.


For connector elements, the following element output variables are available:
PHCTF

Magnitude and phase angle of connector total forces.

PHCEF

Magnitude and phase angle of connector elastic forces.

PHCVF

Magnitude and phase angle of connector viscous forces.

PHCRF

Magnitude and phase angle of connector reaction forces.

PHCSF

Magnitude and phase angle of connector friction forces.

PHCU

Magnitude and phase angle of connector relative displacements.

PHCCU

Magnitude and phase angle of connector constitutive displacements.

PHCV

Magnitude and phase angle of connector relative velocities.

PHCA

Magnitude and phase angle of connector relative accelerations.


Nodal variables:
PU

Magnitude and phase angle of all displacement/rotation components at a node.

PPOR

Magnitude and phase angle of the fluid, pore, or acoustic pressure at a node.

PHPOT

Magnitude and phase angle of the electrical potential at a node.

PRF

Magnitude and phase angle of all reaction forces/moments at a node.

PHCHG

Magnitude and phase angle of the reactive charge at a node.


Element energy densities (such as the elastic strain energy density, SENER), whole element energies (such as the total kinetic energy of an element, ELKE), and NFORC (internal forces at the nodes of the elements) are not available for output in a direct-solution steady-state dynamic analysis.

Whole model variables such as ALLIE (total strain energy) are available for direct-solution steady-state dynamic analysis by requesting energy output to the data, results, or output database files (see Output to the data and results files, Section 4.1.2, and Output to the output database, Section 4.1.3).

Input file template

*HEADING*AMPLITUDE, NAME=loadamp
Data lines to define an amplitude curve as a function of frequency (cycles/time)
**
*STEP, NLGEOM
Include the NLGEOM parameter so that stress stiffening effects will
be included in the steady-state dynamic step
*STATIC
**Any general analysis procedure can be used to preload the structure*CLOAD and/or *DLOAD
Data lines to prescribe preloads
*TEMPERATURE and/or *FIELD
Data lines to define values of predefined fields for preloading the structure
*BOUNDARY
Data lines to specify boundary conditions to preload the structure*END STEP
**
*STEP
*STEADY STATE DYNAMICS, DIRECT
Data lines to specify frequency ranges and bias parameters
*BOUNDARY, LOAD CASE=1
Data lines to specify real (in-phase) boundary conditions
*BOUNDARY, LOAD CASE=2
Data lines to specify imaginary (out-of-phase) boundary conditions
*CLOAD, AMPLITUDE=loadamp
Data lines to specify sinusoidally varying, frequency-dependent, concentrated loads
*CLOAD and/or *DLOAD
Data lines to specify sinusoidally varying loads*END STEP