User subroutines:
are provided to increase the functionality of several ABAQUS capabilities for which the usual data input methods alone may be too restrictive;
provide an extremely powerful and flexible tool for analysis;
are typically written as FORTRAN code and must be included in a model when you execute the analysis, as discussed below;
must be included and, if desired, can be revised in a restarted run, since they are not saved to the restart files (see Restarting an analysis, Section 9.1.1);
cannot be called one from another; and
can in some cases call utility routines that are also available in ABAQUS (see Available utility routines, Section 13.2.3).
You can include one or more user subroutines in a model by specifying the name of a FORTRAN source or object file that contains the subroutines. Details are provided in Execution procedure for ABAQUS/Standard and ABAQUS/Explicit, Section 3.2.2.
Input File Usage: | Enter the following input on the command line: |
abaqus job=job-name user={source-file | object-file} |
ABAQUS/CAE Usage: | Job module: job editor: General: User subroutine file |
In ABAQUS/Standard it is sometimes desirable to set up the FORTRAN environment and manage interactions with external data files that are used in conjunction with user subroutines. For example, there may be history-dependent quantities to be computed externally, once per increment, for use during the analysis; or output quantities that are accumulated over multiple elements in COMMON block variables within user subroutines may need to be written to external files at the end of a converged increment for postprocessing. Such operations can be performed with user subroutine UEXTERNALDB. This user interface can potentially be used to exchange data with another code, allowing for “stagger” between ABAQUS/Standard and another code.
User subroutines should be written with great care. To ensure their successful implementation, the rules and guidelines below should be followed. For a detailed discussion of the individual subroutines, including coding interfaces and requirements, refer to the ABAQUS User Subroutines Reference Manual.
Every ABAQUS/Standard user subroutine must include the statement
include 'aba_param.inc'as the first statement after the argument list.
Every ABAQUS/Explicit user subroutine must include the statement
include 'vaba_param.inc'as the first statement after the argument list.
If variables are exchanged between the main user subroutine and subsequent subroutines, the user should specify the above include statement in all the subroutines to preserve precision.
The files aba_param.inc and vaba_param.inc are installed on the system by the ABAQUS installation procedure and contain important installation parameters. These statements tell the ABAQUS execution procedure, which compiles and links the user subroutine with the rest of ABAQUS, to include the aba_param.inc or vaba_param.inc file automatically. It is not necessary to find the file and copy it to any particular directory; ABAQUS will know where to find it.
If user subroutines call other subroutines or use COMMON blocks to pass information, such subroutines or COMMON blocks should begin with the letter K since this letter is never used to start the name of any subroutine or COMMON block in ABAQUS.
User subroutines must perform their intended function without overwriting other parts of ABAQUS. In particular, you should redefine only those variables identified in this chapter as “variables to be defined.” Redefining “variables passed in for information” will have unpredictable effects.
If problems are encountered during compilation or linking of the subroutine, make sure that the ABAQUS environment file (the default location for this file is the site subdirectory of the ABAQUS installation) contains the correct compile and link commands as specified in the ABAQUS Installation and Licensing Guide. These commands should have been set up by the ABAQUS site manager during installation. The number and type of arguments must correspond to what is specified in the documentation. Mismatches in type or number of arguments may lead to platform-dependent linking or runtime errors.
When developing user subroutines, test them thoroughly on smaller examples in which the user subroutine is the only complicated aspect of the model before attempting to use them in production analysis work.
If needed, debug output can be written to the ABAQUS/Standard message (.msg) file using FORTRAN unit 7 or to the ABAQUS/Standard data (.dat) file or the ABAQUS/Explicit status (.sta) file using FORTRAN unit 6; these units should not be opened by your routines since they are already opened by ABAQUS.
FORTRAN units 15 through 18 or units greater than 100 can be used to read or write other user-specified information. The use of other FORTRAN units may interfere with ABAQUS file operations; see FORTRAN unit numbers used by ABAQUS, Section 3.6.1. You must open these FORTRAN units; and because of the use of scratch directories, the full pathname for the file must be used in the OPEN statement.
Utility routine XIT (ABAQUS/Standard) or XPLB_EXIT (ABAQUS/Explicit) should be used instead of STOP when terminating an analysis from within a user subroutine. This will ensure that all files associated with the analysis are closed properly (Terminating an analysis, Section 2.1.12 of the ABAQUS User Subroutines Reference Manual).
An ABAQUS model can be defined in terms of an assembly of part instances (see Defining an assembly, Section 2.9.1).
Although a local coordinate system can be defined for each part instance, all variables (such as current coordinates) are passed to a user subroutine in the global coordinate system, not in a part-local coordinate system. The only exception to this rule is when the user subroutine interface specifically indicates that a variable is in a user-defined local coordinate system (Orientations, Section 2.2.5, or Transformed coordinate systems, Section 2.1.5). The local coordinate system originally may have been defined relative to a part coordinate system, but it was transformed according to the positioning data given for the part instance. As a result, a new local coordinate system was created relative to the assembly (global) coordinate system. This new coordinate system definition is the one used for local orientations in user subroutines.
The node and element numbers passed to a user subroutine are internal numbers generated by ABAQUS. These numbers are global in nature; all internal node and element numbers are unique. If the original number and the part instance name are required, call the utility subroutine GETPARTINFO (ABAQUS/Standard) or VGETPARTINFO (ABAQUS/Explicit) from within your user subroutine (see Obtaining part information, Section 2.1.4 of the ABAQUS User Subroutines Reference Manual). The expense of calling these routines is not trivial, so minimal use of them is recommended.
Another utility subroutine, GETINTERNAL (ABAQUS/Standard) or VGETINTERNAL (ABAQUS/Explicit), can be used to retrieve the internal node or element number corresponding to a given part instance name and local number.
Set and surface names passed to user subroutines are always prefixed by the assembly and part instance names, separated by underscores. For example, a surface named surf1 belonging to part instance Part1-1 in assembly Assembly1 will be passed to a user subroutine as
Assembly1_Part1-1_surf1
Solution-dependent state variables are values that can be defined to evolve with the solution of an analysis.
Any number of solution-dependent state variables can be used in the following user subroutines:
The state variables can be defined as a function of any other variables appearing in these subroutines and can be updated accordingly. Solution-dependent state variables should not be confused with field variables, which may also be needed in the constitutive routines and can vary with time; field variables are discussed in detail in Predefined fields, Section 27.6.1.Solution-dependent state variables used in VFRIC and VUINTER are defined as state variables at slave nodes and are updated with other contact variables.
You must allocate space for each of the solution-dependent state variables at every applicable integration point or contact slave node.
Separate user subroutine groups have been identified that differ in the way the number of solution-dependent state variables is defined. These groups are described below. Solution-dependent state variables can be shared by subroutines within the same group; they cannot be shared between subroutines belonging to different groups.
Input File Usage: | For most subroutines the number of such variables required at the points or nodes is entered as the only value on the data line of the *DEPVAR option, which should be included as part of the material definition for every material in which solution-dependent state variables are to be considered: |
*DEPVAR For subroutines that do not use the material behavior defined with the *MATERIAL option, the *DEPVAR option is not used. For subroutine UEL: *USER ELEMENT, VARIABLES=number of variables For subroutine UGENS: *SHELL GENERAL SECTION, USER, VARIABLES=number of variables For subroutines FRIC and VFRIC: *FRICTION, USER, DEPVAR=number of variables For subroutines UINTER and VUINTER: *SURFACE INTERACTION, USER, DEPVAR=number of variables |
ABAQUS/CAE Usage: | For most subroutines the number of such variables required at the points or nodes is entered as part of the material definition for every material in which solution-dependent state variables are to be considered: |
Property module: material editor: GeneralDepvar: Number of solution-dependent state variables |
You can define the initial values of solution-dependent state variable fields directly or in ABAQUS/Standard through a user subroutine. The initial values of solution-dependent state variables for contact in ABAQUS/Explicit are assigned as zero internally.
You can define the initial values in a tabular format for elements and/or element sets. See Initial conditions, Section 27.2.1, for additional details.
Input File Usage: | *INITIAL CONDITIONS, TYPE=SOLUTION |
For complicated cases in ABAQUS/Standard you can call user subroutine SDVINI so that dependencies on coordinates, element numbers, etc. can be used in the definition of the variable field.
Input File Usage: | *INITIAL CONDITIONS, TYPE=SOLUTION, USER |
User-defined, solution-dependent state variables can be written to the data file (.dat), the output database file (.odb), and the results file (.fil); the output identifiers SDV and SDVn are available as element integration variables (see ABAQUS/Standard output variable identifiers, Section 4.2.1, and ABAQUS/Explicit output variable identifiers, Section 4.2.2). These variables are not available for user subroutines VFRIC and VUINTER.
Alphanumeric data, such as labels (names) of surfaces or materials, are always passed into user subroutines in the upper case. As a result, direct comparison of these labels with corresponding lower-case characters will fail. Upper case must be used for all such comparisons. An example of such a comparison can be found in UMAT, Section 1.1.31 of the ABAQUS User Subroutines Reference Manual. It illustrates the code setup inside user subroutine UMAT when more than one user-defined material model needs to be defined. The variable CMNAME is compared against MAT1 and MAT2 (even in situations where the material names may have been defined as mat1 and mat2, respectively.)
ABAQUS/Explicit is installed with both single precision and double precision executables. To use the double precision executable, you must specify double precision when you run the analysis (see Execution procedure for ABAQUS/Standard and ABAQUS/Explicit, Section 3.2.2). All variables in the user subroutines that start with the letters a to h and o to z will automatically be defined in the precision of the executable that you run. The precision of the executable is defined in the vaba_param.inc file, and it is not necessary to define the precision of the variables explicitly.
ABAQUS/Explicit user subroutines are written with a vector interface, which means that blocks of data are passed to the user subroutines. For example, the vectorized user material routine (VUMAT) is passed stresses, strains, state variables, etc. for nblock material points. One of the parameters defined by vaba_param.inc is maxblk, the maximum block size. If the user subroutine requires the dimensioning of temporary arrays, they can be dimensioned by maxblk.
User subroutines can be used when running ABAQUS/Explicit in parallel. However, the use of common block statements in the user subroutines or in subroutines called by the user subroutines must be avoided since it will result in unpredictable behavior of the executable.
Most of the user subroutines available in ABAQUS are called at least once for each increment during an analysis step. However, as discussed below, many subroutines are called more or less often.
Most user subroutines that are used to define material, element, or interface behavior are called twice per material point, element, or slave surface node in the first iteration of every increment such that the model's initial stiffness matrix can be formulated appropriately for the step procedure chosen. The subroutines are called only once per material point, element, or slave surface node in each succeeding iteration within the increment.
By default, in transient implicit dynamic analyses (Implicit dynamic analysis using direct integration, Section 6.3.2) ABAQUS/Standard calculates accelerations at the beginning of each dynamic step. ABAQUS/Standard must call user subroutines that are used to define material, element, or interface behavior two extra times for each material point, element, or slave surface node prior to the zero increment. The extra calls to the user subroutines are not made if the initial acceleration calculations are suppressed. If the half-step residual tolerances are being checked in a transient implicit dynamic step, ABAQUS/Standard must call these user subroutines one extra time for each material point, element, or slave surface node at the end of each increment. If the calculation of the half-step residual is suppressed, the extra call to the user subroutines is not made.
User subroutines UHARD, UHYPEL, UHYPER, and UMULLINS, when used in plane stress analyses, are called more often.
User subroutines that are used to define initial conditions or orientations are called before the first iteration of the first step's initial increment within an analysis.
User subroutines that are used to define predefined fields are called prior to the first iteration of the relevant step's first increment for all iterations of all increments whenever the current field variable is needed.
If there is any doubt as to how often a user subroutine is called, this information can be obtained upon testing the subroutine on a small example, as suggested earlier. The current step and increment numbers are commonly passed into these subroutines, and they can be printed out as debug output (also discussed earlier). The iteration number for which the subroutine is called may not be passed into the user subroutine; however, if printed output is sent from the subroutine to the message (.msg) file (Output, Section 4.1.1), the location of the output within this file will give the iteration number, provided that the output to the message file is written at every increment.
A variety of utility routines are available to assist in the coding of user subroutines. You include the utility routine inside a user subroutine. When called, the utility routine will perform a predefined function or action whose output or results can be integrated into the user subroutine. Some utility routines are only applicable to particular user subroutines. Each utility routine is discussed in detail in Utility routines, Section 2.1 of the ABAQUS User Subroutines Reference Manual.