This option is used to define detonation points for a JWL explosive equation of state. It is required when the *EOS, TYPE=JWL option is used. The *DETONATION POINT option should appear immediately after the *EOS option.
Product: ABAQUS/Explicit
Type: Model data
Level: Model
First line:
Coordinate 1 of detonation point.
Coordinate 2 of detonation point.
Coordinate 3 of detonation point.
Detonation delay time (total time, as defined in Conventions, Section 1.2.2 of the ABAQUS Analysis User's Manual). The default is 0.
Repeat this data line as often as necessary to define each detonation point.