16.4 Creating and modifying prescribed conditions

To create a load, boundary condition, or predefined field, select Create from the appropriate menu in the main menu bar. A Create dialog box will appear in which you can provide a name for the prescribed condition and choose the type of the prescribed condition that you want to create.

When you click Continue in the Create dialog box, you are prompted to select the region to which you want to apply the prescribed condition, unless the prescribed condition is applied to the whole model. You can apply connector loads and connector boundary conditions only to wires that are associated with a connector section assignment. If you are select multiple wires, the connector sections assigned to the wires in the connector section assignments must have the available components of relative motion for which you are defining loads and boundary conditions. Once you have selected the region, an editor appears in which you can specify additional information about the prescribed condition, such as its magnitude.

The top panel of each prescribed condition editor displays the name and type of the prescribed condition, the analysis step you are currently in, and the region of the model to which the prescribed condition will be applied. If you are editing a prescribed condition in the step in which it was first created, an Edit Region button appears next to the Region field; this button allows you to edit the region to which the prescribed condition is applied. If the prescribed condition is applied to the whole model, the Edit Region button is not applicable and, hence, does not appear. (For more information, see Editing the region to which a prescribed condition is applied, Section 16.8.4.)

The format of the rest of the editor depends on the type of prescribed condition you are defining and on the step specified at the top of the editor. For example, the editor for concentrated forces is shown in Figure 16–2.

Figure 16–2 The editor for concentrated forces.

This editor contains special text fields in which you can specify the components of the force in the 1-, 2-, and 3-directions. The editor also contains an Amplitude text field that allows you to vary the magnitude of the prescribed condition as a function of time. You can accept the default amplitude, select an amplitude that you have defined using the Amplitude toolset, or click Create to define a new amplitude. (For more information, see Chapter 38, The Amplitude toolset.”)

You can specify the coordinate system in which you will apply the following loads or boundary conditions:

All other prescribed conditions use the global coordinate system, with the exception of pressures, which are applied normal to the selected surfaces.

If the load or boundary condition allows you to specify the coordinate system, you can select an existing datum coordinate system or you can accept the global coordinate system. If the desired datum coordinate system does not exist, you can create it using the Datum toolset. (For more information, see Creating datum coordinate systems, Section 40.9.) Alternatively, you can refer to an ABAQUS/Standard user subroutine that defines the coordinate system (see ORIENT, Section 1.1.14 of the ABAQUS User Subroutines Reference Manual).

Note:  If you delete or suppress the datum coordinate system, the orientation of the load or boundary condition reverts to the global coordinate system.

The rules for creating and modifying predefined fields vary depending on the predefined field type:

Note:  If you do not define initial values for a predefined field, that field is assumed to have a value of zero at the start of the analysis.

Once you have created a prescribed condition, you can modify the prescribed condition in the following ways:

To display help on a particular manager or editor feature, select HelpOn Context from the main menu bar and then click the feature of interest.


For information on related topics, click any of the following items: