14.4.5 Creating and modifying output requests

To create an output request, select OutputField Output RequestsCreate or OutputHistory Output RequestsCreate from the main menu bar. An editor appears in which you can enter all of the information necessary to define the output request. The top of the editor displays the following:

For example, the Field Output Request editor is shown in Figure 14–3.

Figure 14–3 The Field Output Request editor.

The Domain section of the editor allows you to choose the region from which output will be generated. You can request that ABAQUS write field data to the output database for the whole model or for the following:

Similarly, you can request that ABAQUS write history data to the output database for the whole model or for the following:

The Output Variables section of the editor contains a list of the variable categories that are applicable to the step procedure and the selected domain. Choose one of the following:

Note:  In addition to the current analysis procedure, other aspects of the model may affect the preselected default output variables. For example, if an output variable is valid for the analysis procedure but is not valid for the element type used in the mesh, ABAQUS will remove that variable during the analysis.

If you use the Field Output Request editor to select a vector or tensor variable to be included in a field output request, ABAQUS automatically writes all components of that variable to the output database during the step. For example, if you select the vector U in a three-dimensional model, ABAQUS outputs the three displacement components U1, U2, and U3 to the output database along with the three rotation components UR1, UR2, and UR3.

In contrast, if you use the History Output Request editor to select a vector or tensor variable to be included in a history output request, the History Output Request editor allows you to select individual components of the variable. It is useful to specify individual components in a history output request because these variables are typically output very frequently—possibly as often as every increment.

If your model contains rebar, you must toggle on Output for rebar to include rebar output in the data that ABAQUS writes to the output database and to view plots of the rebar orientations in the Visualization module.

The editor also allows you to specify the section points from which output will be obtained and the frequency at which the output is written to the output database.

For example, in Figure 14–3 the user is editing a field output request that is associated with a Static, General analysis procedure. The user has selected all of the variables in the Stresses category. These variables will be included in the output request during the step named Side Load. ABAQUS will write output from the default section points at every increment.

For detailed instructions on selecting output variables and components, see the following sections:

Once you have created an output request, you can modify it in the following ways:

If you modify an output request during the step in which you created the request, you can modify the domain, the output variables, the output for rebar option, the section points, and the output frequency. However, if you modify an output request during a step into which it was propagated, you can modify only the output variables and the output frequency.

When you request output from a contour integral, the History Output Request editor allows you to select only the frequency of output, the number of contour integrals, and the type of contour integral calculation. For more information, see Requesting contour integral output, Section 20.1.13.


For information on related topics, click the following item: