Products: ABAQUS/Standard ABAQUS/Explicit
ABAQUS/Standard allows heat flow across an interface via conduction or radiation. Generally, both modes of heat transfer are present to some degree. Regardless of the mode, heat transfer across the interface is assumed to occur only in the normal direction.
Heat conduction across the interface is assumed to be defined by
The derivatives of are
The heat flow per unit area between corresponding points is assumed to be given by
The derivatives of are
The contribution to the variational statement of thermal equilibrium is
For “tied” thermal contact the temperature at point is constrained to have the same temperature as point . The Lagrange multiplier method is used to impose the constraint by augmenting the thermal equilibrium statement as follows: