*SUBSTRUCTURE LOAD CASE
Begin the definition of a substructure load case.

This option is used to begin the definition of a substructure load case for the substructure currently being generated. It can be used only in a *SUBSTRUCTURE GENERATE analysis.

Product: ABAQUS/Standard  

Type: History data

Level: This option is not supported in a model defined in terms of an assembly of part instances.

References:

Required parameter:

NAME

Set this parameter equal to the name that will be used in referring to the load case in *SLOAD option specifications when applying loads to the substructure during an analysis.

To define the loads or boundary conditions: 

Enter any mechanical loading options (Concentrated loads, Section 19.4.2 of the ABAQUS Analysis User's Manual, and Distributed loads, Section 19.4.3 of the ABAQUS Analysis User's Manual), thermal loading options (Thermal loads, Section 19.4.4 of the ABAQUS Analysis User's Manual), or *BOUNDARY options (Boundary conditions, Section 19.3.1 of the ABAQUS Analysis User's Manual) to define the loads forming the load case. Specify a magnitude for each load. This magnitude will be scaled by a magnitude and amplitude reference specified in the *SLOAD option. The load case definition continues until an option is encountered that is not one of the loading options. If boundary conditions are included in a *SUBSTRUCTURE LOAD CASE, they are always active, even if the *SUBSTRUCTURE LOAD CASE option is not used.