This option is used to define the properties of fluid link elements.
Products: ABAQUS/Standard ABAQUS/Explicit
Type: Model data
Level: Part Part Instance
Set this parameter equal to the name of the element set containing the fluid link elements for which properties are being defined.
Set this parameter equal to the number of field variables included in the specification of the mass flow rate. If this parameter is omitted, the mass flow rate is assumed not to depend on any field variables but may still depend on average pressure and average temperature. See Specifying field variable dependence” in “Material data definition, Section 9.1.2 of the ABAQUS Analysis User's Manual, for more information.
Set TYPE=FUNCTION (default) to specify a functional relationship between mass flow rate and pressure difference.
Set TYPE=TABULAR to specify a table of mass flow rate versus pressure difference.
First line:
.
.
Average pressure, , if pressure dependent.
Average temperature, , if temperature dependent.
First field variable.
Second field variable.
Etc., up to four field variables.
Subsequent lines (only needed if the DEPENDENCIES parameter has a value greater than four):
Fifth field variable.
Etc., up to eight field variables per line.
Repeat this set of data lines as often as necessary to specify and as functions of , , and field variables.
First line:
Mass flow rate, .
Pressure difference, .
Average pressure, , if pressure dependent.
Average temperature, , if temperature dependent.
First field variable.
Second field variable.
Etc., up to four field variables.
Subsequent lines (only needed if the DEPENDENCIES parameter has a value greater than four):
Fifth field variable.
Etc., up to eight field variables per line.
Repeat this set of data lines as often as necessary to specify as a function of , , , and field variables.