sensors to measure concentration | sensors to measure concentration | ||
*** Test on substance like ethanol that the sensors are designed for | *** Test on substance like ethanol that the sensors are designed for | ||
− | *** If accuracy and precision are sufficient for source localization, | + | *** If accuracy and precision are sufficient for source localization, continue with these sensors, otherwise, we will have to find different sensors |
− | continue with these sensors, otherwise, we will have to find different | ||
− | sensors | ||
*** Test whether acquisition time can be shortened for concentration measurement | *** Test whether acquisition time can be shortened for concentration measurement | ||
− | *** Test whether performance improves with a different experimental | + | *** Test whether performance improves with a different experimental setup (e.g., using a fan to blow air across the sensor) |
− | setup (e.g., using a fan to blow air across the sensor) | + | ** Incorporate digital resistors into the circuit design to allow on-line optimal concentration estimation |
− | ** Incorporate digital resistors into the circuit design to allow | + | ** Program a function in Matlab to estimate the direction to the source from the concentration measurements of two sensor arrays |
− | on-line optimal concentration estimation | ||
− | ** Program a function in Matlab to estimate the direction to the | ||
− | source from the concentration measurements of two sensor arrays | ||
*** Test with simulations in Matlab | *** Test with simulations in Matlab | ||
− | ** Incorporate the direction estimation into a guidance program for | + | ** Incorporate the direction estimation into a guidance program for the robotic platform |
− | the robotic platform | ||
*** The robot should move to seek out the source of the odor | *** The robot should move to seek out the source of the odor | ||
− | *** It should update its direction of movement periodically according to | + | *** It should update its direction of movement periodically according to new direction estimates |
− | new direction estimates |
Revision as of 16:01, 22 January 2010
- Team Members: Joy Chiang
- PhD Supervisor: Vanessa
- Faculty Supervisor: Arye Nehorai
- Goal:
- Determine the ability (accuracy and precision) of the current
sensors to measure concentration
- Test on substance like ethanol that the sensors are designed for
- If accuracy and precision are sufficient for source localization, continue with these sensors, otherwise, we will have to find different sensors
- Test whether acquisition time can be shortened for concentration measurement
- Test whether performance improves with a different experimental setup (e.g., using a fan to blow air across the sensor)
- Incorporate digital resistors into the circuit design to allow on-line optimal concentration estimation
- Program a function in Matlab to estimate the direction to the source from the concentration measurements of two sensor arrays
- Test with simulations in Matlab
- Incorporate the direction estimation into a guidance program for the robotic platform
- The robot should move to seek out the source of the odor
- It should update its direction of movement periodically according to new direction estimates