This option is used to define a locking criterion for connector elements that have available components of relative motion.
Products: ABAQUS/Standard ABAQUS/Explicit
Type: Model data
Level: Model
Set this parameter equal to the component number on which a locking criterion is based. See Connection-type library, Section 25.1.5 of the ABAQUS Analysis User's Manual, for components of relative motion definitions.
This parameter applies only to ABAQUS/Explicit analyses.
Set this parameter equal to the number of field variable dependencies included in the definition of the connector lock data, in addition to temperature. If this parameter is omitted, it is assumed that the connector lock is independent of field variables. See Specifying field variable dependence” in “Material data definition, Section 16.1.2 of the ABAQUS Analysis User's Manual, for more information.
Set this parameter equal to ALL (default) to lock all components of relative motion when the locking criterion is satisfied.
Set this parameter equal to an available component number to lock only that component of relative motion when the locking criterion is satisfied.
First (and only) line for ABAQUS/Standard:
Lower bound on the connector's relative position specified by the COMPONENT parameter. By default, no lower bound is used for the selected component.
Upper bound on the connector's relative position specified by the COMPONENT parameter. By default, no upper bound is used for the selected component.
Lower bound on the force or moment in the direction indicated by the COMPONENT parameter. By default, no lower bound is used for the selected force or moment.
Upper bound on the force or moment in the direction indicated by the COMPONENT parameter. By default, no upper bound is used for the selected force or moment.
Data lines for ABAQUS/Explicit:
Lower bound on the connector's relative position specified by the COMPONENT parameter. By default, no lower bound is used for the selected component.
Upper bound on the connector's relative position specified by the COMPONENT parameter. By default, no upper bound is used for the selected component.
Lower bound on the force or moment in the direction indicated by the COMPONENT parameter. By default, no lower bound is used for the selected force or moment.
Upper bound on the force or moment in the direction indicated by the COMPONENT parameter. By default, no upper bound is used for the selected force or moment.
Lower bound on velocity in the direction specified by the COMPONENT parameter. By default, no lower bound is used for the selected velocity.
Upper bound on velocity in the direction specified by the COMPONENT parameter. By default, no upper bound is used for the selected velocity.
Temperature.
First field variable.
Subsequent lines (only needed if the DEPENDENCIES parameter has a value greater than one):
Second field variable.
Etc., up to eight field variables per line.
Repeat this set of data lines as often as necessary to define the lock criterion as a function of temperature, and other predefined field variables.