*HEADING TWO DIMENSIONAL HEAT TRANSFER INTERFACE (CPE4RT) GAP CONDUCTANCE PENALTY CONTACT ** ** The temperature at the NOUT nodes, based on a 1D model is: ** NT_out=100+HFL2*R_th; R_th=L/(kA); ** See ch. 1.7.1 of ABAQUS/Verification Manual ** *NODE,NSET=NALL 1,10.,0.0 2,11.0,0.0 3,11.0,.5 4,10.0,0.5 7,11.,1.0 8,10.,1.0 11,10.,-0.1 12,11.,-0.1 17,11.,-1.0 18,10.,-1.0 *NSET, NSET=SIDE3 7,8 *NSET, NSET=BOT 11,12,17,18 *NSET,NSET=QA_TEST 1,2 *NSET,NSET=NOUT QA_TEST, *ELEMENT,TYPE=CPE4RT,ELSET=MID 1,1,2,3,4 *ELEMENT,TYPE=CPE4RT,ELSET=TOP 2,4,3,7,8 *ELEMENT,TYPE=CPE4RT,ELSET=BOT 3,18,17,12,11 *ELSET, ELSET=TOP 1,2 *ELSET, ELSET=SOLID 1,2,3 *SOLID SECTION,ELSET=SOLID,MATERIAL=SOLMAT *MATERIAL,NAME=SOLMAT *CONDUCTIVITY 1., *SPECIFIC HEAT 46., *DENSITY 7850., *ELASTIC 1.0,0.0 *SURFACE,TYPE=ELEMENT, NAME=SURF3 MID,S1 *SURFACE,TYPE=ELEMENT, NAME=SURF4 BOT,S3 *STEP *DYNAMIC TEMPERATURE-DISPLACEMENT, EXPLICIT ,300000. *CONTACT PAIR, INTERACTION=GAP,WEIGHT=1.0,MECHANICAL CONSTRAINT=PENALTY SURF3,SURF4 *SURFACE INTERACTION, NAME=GAP *GAP CONDUCTANCE 10.,0. 10.,10. *BOUNDARY,OP=NEW SIDE3,11,,100. BOT,11,,50. ****************************** *FILE OUTPUT, NUM=1 *NODE FILE,NSET=NOUT NT, ***************************** *OUTPUT,FIELD,NUM=1 *NODE OUTPUT,NSET=QA_TEST NT *NODE OUTPUT,NSET=NALL NT ******************************** ***OUTPUT, HISTORY,TIME INTERV=1E4 ***NODE OUTPUT, NSET=NOUT **NT, ***ELEMENT OUTPUT, ELSET=TOP **HFL2, ******** *OUTPUT, HISTORY,TIME INTERV=3.0E5 *ENERGY OUTPUT,VAR=ALL ******** *ENDSTEP