This option is used to define the behavior of GAP-type elements.
Product: ABAQUS/Standard
Type: Model data
Level: Part Part Instance
Set this parameter equal to the name of the element set containing the GAP-type contact elements for which properties are being defined.
First (and only) line:
Initial clearance, .
If the remaining fields are omitted or specified as zero, the contact direction will be computed from the nodal coordinates.
Global -direction cosine of the contact direction.
Global -direction cosine of the contact direction.
Global -direction cosine of the contact direction.
Element cross-sectional area.
First (and only) line:
Minimum/maximum separation distance, .
Global -direction cosine of the cylinder axis.
Global -direction cosine of the cylinder axis.
Global -direction cosine of the cylinder axis.
Element cross-sectional area.