*FLUID EXPANSION
Specify the thermal expansion coefficient for a hydraulic fluid.

This option is used to define thermal expansion coefficients for the hydraulic fluid model. It can be used only in conjunction with the *FLUID BEHAVIOR option or the *FLUID PROPERTY option.

Products: ABAQUS/Standard  ABAQUS/Explicit  

Type: Model data

Level: Part  Part Instance  

References:

Optional parameters:

DEPENDENCIES

Set this parameter equal to the number of field variable dependencies included in the definition of the thermal expansion coefficient, in addition to temperature. If this parameter is omitted, it is assumed that the thermal expansion coefficient depends only on temperature. See Specifying field variable dependence” in “Material data definition, Section 9.1.2 of the ABAQUS Analysis User's Manual, for more information.

ZERO

Set this parameter equal to the value of . The default is ZERO=0.

Data lines to define the thermal expansion coefficient: 

First line:

  1. Mean coefficient of thermal expansion, .

  2. Temperature, .

  3. First field variable.

  4. Etc., up to six field variables.

Subsequent lines (only needed if the DEPENDENCIES parameter has a value greater than six):

  1. Seventh field variable.

  2. Etc., up to eight field variables per line.

Repeat this set of data lines as often as necessary to specify as a function of and field variables.