This option is used to define fluid exchange between two fluid cavities or between a fluid cavity and its environment.
Product: ABAQUS/Explicit
Type: Model data
Level: Model
Set this parameter equal to a name that will be used to refer to the fluid exchange definition.
Set this parameter equal to the name of the *FLUID EXCHANGE PROPERTY option defining the fluid exchange property.
Set this parameter equal to the total orifice area or the total effective area.
The default value is 1.0 if a surface is not specified. Otherwise, the default value is equal to the area of the surface. If both the effective area and a surface are specified, the area of the surface is ignored.
Set this parameter equal to the name of the surface representing the orifice or effective area. If this parameter is omitted, the value specified with the EFFECTIVE AREA parameter is used for the orifice or effective area.
First (and only) line:
First reference node number of fluid cavity.
Optional second reference node number of fluid cavity. If only one node is specified, fluid exchange will occur between the fluid cavity and its environment.